Explore equipment, consumables and technical specifications for industrial procurement. Select your requirements and request a quotation.

Representative image from another reference in this family; not this model. Retained source illustration. Series illustration; not an exact model or configuration photograph.
View the illustrated source reference: Quincy QPNC-13 Non-Cycling Refrigerated Air Dryer
Quincy Compressor
Source-backed reference
QPVS-6400 is a Quincy variable-speed refrigerated compressed-air dryer. The cited model row provides 6400 CFM at 100 PSIG with air/water cooling and 8” Flange connections. Selection must use the actual flow duty and the manufacturer’s correction tables.
- Rated flow
- 6400 CFM at 100 PSIGModel suffix is an identifier, not necessarily the printed rated flow.
- Cooling and refrigerant
- Air/Water; R410AAir/Water is the printed row label; no unlisted cooling execution or variant performance is inferred.
- Pressure, electrics and connections
- Maximum 203 PSIG; electrical column Multiple; 8” FlangeMultiple does not establish a particular voltage, phase or frequency.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Series illustration; not an exact model or configuration photograph.
View the illustrated source reference: Quincy QPNC-13 Non-Cycling Refrigerated Air Dryer
Quincy Compressor
Source-backed reference
QPVS-8500 is a Quincy variable-speed refrigerated compressed-air dryer. The cited model row provides 8500 CFM at 100 PSIG with air/water cooling and 8” Flange connections. Selection must use the actual flow duty and the manufacturer’s correction tables.
- Rated flow
- 8500 CFM at 100 PSIGModel suffix is an identifier, not necessarily the printed rated flow.
- Cooling and refrigerant
- Air/Water; R410AAir/Water is the printed row label; no unlisted cooling execution or variant performance is inferred.
- Pressure, electrics and connections
- Maximum 203 PSIG; electrical column Multiple; 8” FlangeMultiple does not establish a particular voltage, phase or frequency.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QRHT 25 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 25 CFM at 100 PSIGMain table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 25 SCFM at 50°F PDP; 20 SCFM at 40°F PDPSCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 0.42 kW; maximum 232 PSIGExact model electrical execution.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QRHT 50 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 50 CFM at 100 PSIGMain table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 50 SCFM at 50°F PDP; 40 SCFM at 40°F PDPSCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 0.84 kW; maximum 232 PSIGExact model electrical execution.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QRHT 75 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 75 CFM at 100 PSIGMain table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 75 SCFM at 50°F PDP; 60 SCFM at 40°F PDPSCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 1.53 kW; maximum 232 PSIGExact model electrical execution.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QRHT 100 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 100 CFM at 100 PSIGMain table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 100 SCFM at 50°F PDP; 80 SCFM at 40°F PDPSCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 1.63 kW; maximum 232 PSIGExact model electrical execution.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QRHT 125 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 125 CFM at 100 PSIGMain table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 125 SCFM at 50°F PDP; 100 SCFM at 40°F PDPSCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 2.02 kW; maximum 232 PSIGExact model electrical execution.
Request a quotation →

Retained source illustration. Generic manufacturer illustration; not an exact model photograph.
Quincy Compressor
Source-backed reference
QSI-50 is a Quincy fixed-speed rotary-screw compressor. Its 50 hp / 37 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 275.1 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 240.6 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 50 hp; 37 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-60 is a Quincy fixed-speed rotary-screw compressor. Its 60 hp / 45 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 338.6 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 293.4 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 60 hp; 45 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-75 is a Quincy fixed-speed rotary-screw compressor. Its 75 hp / 55 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 390.2 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 357.9 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 75 hp; 55 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-100 is a Quincy fixed-speed rotary-screw compressor. Its 100 hp / 75 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 512.3 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 467.1 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 100 hp; 75 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-125 is a Quincy fixed-speed rotary-screw compressor. Its 125 hp / 90 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 614.7 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 557.5 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 125 hp; 90 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-150 is a Quincy fixed-speed rotary-screw compressor. Its 150 hp / 110 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 769.0 ACFM with pressure column 110/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 678.3 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 150 hp; 110 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-175 is a Quincy fixed-speed rotary-screw compressor. Its 175 hp / 132 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 870.0 ACFM with pressure column 110/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 791.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 175 hp; 132 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-200 is a Quincy fixed-speed rotary-screw compressor. Its 200 hp / 160 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 996.9 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 917.5 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 200 hp; 160 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Series illustration; not an exact model or configuration photograph.
View the illustrated source reference: Quincy QGS-5 Rotary Screw Air Compressor 5 HP
Quincy Compressor
Source-backed reference
QSI-250 is a Quincy fixed-speed rotary-screw compressor. Its 250 hp / 185 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 1273.0 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 1205.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 250 hp; 185 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-300 is a Quincy fixed-speed rotary-screw compressor. Its 300 hp / 220 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 1603.0 ACFM with pressure column 110/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 1498.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 300 hp; 220 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-350 is a Quincy fixed-speed rotary-screw compressor. Its 350 hp / 260 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 1805.2 ACFM with pressure column 110/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 1655.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 350 hp; 260 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QSI-400 is a Quincy fixed-speed rotary-screw compressor. Its 400 hp / 315 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 2011.3 ACFM with pressure column 100/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Published pressure/flow pair
- 1866.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
- Power
- 400 hp; 315 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →
Wellhead Service Tools
Reference configuration — confirm the required execution when enquiring.
Technical example for this source execution only. Confirm the final dimensions, connections, material and service conditions for the enquiry. / مثال فني لهذا التكوين الوارد في المصدر فقط. يرجى تأكيد الأبعاد والوصلات والمادة وظروف الخدمة النهائية للطلب.
- Function / الوظيفة
- Protects casing-head body or spool interior during drilling / تحمي داخل جسم رأس الغلاف أو البكرة أثناء الحفر — This source execution only. / لهذا التكوين الوارد في المصدر فقط.
- Retention requirement / متطلب التثبيت
- Top-flange hold-down screws or hold-down flange with screws / براغي تثبيت في الفلنجة العلوية أو فلنجة تثبيت مزودة ببراغي — This source execution only. / لهذا التكوين الوارد في المصدر فقط.
Request a quotation →
Gas Lift Orifice, Dummy & Equalizing Valves
Reference configuration — confirm the required execution when enquiring.
Documented example execution; listed values apply only to this example. / مثال تنفيذ موثق؛ تنطبق القيم المدرجة على هذا المثال فقط.
- Nominal outside diameter / القطر الخارجي الاسمي
- 1 in
- Upper packing outside diameter / القطر الخارجي للحشوة العلوية
- 1-1/32 in
- Lower packing outside diameter / القطر الخارجي للحشوة السفلية
- 1-1/32 in
Request a quotation →
Submerged-Arc Welding Tractor Carriages
Reference configuration — confirm the required execution when enquiring.
Separately dated brochure tractor/carriage execution; not a complete system or operating procedure. Confirm actual model/code/edition and supplied contents. Manual feed/travel/ambient and brochure control-cable package conflicts stay held. No universal source/interface/track/nozzle/cooling compatibility, certification, warranty, stock or current local supply inference.
- Source process
- Submerged arc — DC
- Source carriage execution
- Standard
- Source input supply
- 115 VAC / 50–60 Hz
Request a quotation →
Submerged-Arc Welding Tractor Carriages
Reference configuration — confirm the required execution when enquiring.
Separately dated brochure tractor/carriage execution; not a complete system or operating procedure. Confirm actual model/code/edition and supplied contents. Manual feed/travel/ambient and brochure control-cable package conflicts stay held. No universal source/interface/track/nozzle/cooling compatibility, certification, warranty, stock or current local supply inference.
- Source process
- Submerged arc — DC
- Source carriage execution
- Track
- Source input supply
- 115 VAC / 50–60 Hz
Request a quotation →
Abrasive Blasting Systems
Reference configuration — confirm the required execution when enquiring.
A contractor-size abrasive blast pot with metered abrasive flow for field surface preparation and blast-room work.
- Vessel capacity (cu ft)
- 6.5
- Controls
- MV3 abrasive metering valve with ComboValve; Thompson Valve II is a separate available configuration
- Supply and air sizing
- No fixed compressor CFM confirmed on this model page. Specify nozzle bore, blast pressure, number of operators and auxiliary demand.
Request a quotation →