Reference overview

QSI-350 is a Quincy fixed-speed rotary-screw compressor. Its 350 hp / 260 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.

Recorded reference facts

Published pressure/flow pair
1805.2 ACFM with pressure column 110/110 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
Published pressure/flow pair
1655.0 ACFM with pressure column 125/128 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred. Slash-separated pressure notation is not defined by this sheet; no rated/max-pressure interpretation or selection interval is assumed.
Power
350 hp; 260 kWPower columns as printed; motor rating versus total package input is not independently established.
Weight
12300 lbPublished package row; final execution and transport requirements need confirmation.
Sound level
82.5 dBAPrinted dBA row; measurement distance/load basis not fully specified here. No site noise guarantee.

Applications

  • Industrial compressed-air generation at the selected pressure and flow.
  • Steady-demand compressed-air systems.

Configurations

  • QSI-350 · Pressure as printed psi: 110/110 · Flow acfm: 1805.2 · Scope: Exact published duty row; no interpolation
  • QSI-350 · Pressure as printed psi: 125/128 · Flow acfm: 1655.0 · Scope: Exact published duty row; no interpolation

Operating conditions and scope

  • The length, width and height columns do not state units. Do not assume the dimensions are in inches.
  • Electrical voltage/phase/frequency and exact installed configuration require manufacturer confirmation.
  • Confirm the meaning of the paired QSI pressure values before selection.