QRHT 125 is a Quincy high-temperature refrigerated air dryer incorporating aftercooling, moisture separation, drainage and a coalescing filter. Select its flow against the required pressure dew point: the manufacturer publishes separate 50°F and 40°F PDP duties.
- Published flow
- 125 CFM at 100 PSIG
Main table CFM label retained separately from SCFM dew-point table.
- Inlet flow by pressure dew point
- 125 SCFM at 50°F PDP; 100 SCFM at 40°F PDP
SCFM and PDP conditions copied as printed; no equivalence to the main CFM column inferred.
- Electrical and pressure limits
- 115/1/60 V / phase / Hz; 2.02 kW; maximum 232 PSIG
Exact model electrical execution.
- Physical connections
- 0.75 NPT (inches); 22.6 × 18.1 × 41 in; approximate weight 238 lb
Dimensions length × width × height; service clearances not included.
- Refrigerant and supplied filter
- R513a; coalescing filter supplied
Source says coalescing filter supplied for all listed QRHT models.
Requested values remain separate from recorded product specifications.