Quincy Compressor

Source-backed reference

Quincy QPNC-30 Non-Cycling Refrigerated Air Dryer

QPNC-30 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 30 CFM at 100 PSIG and specifies 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
30 CFM at 100 PSIG; separate metric column 51 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.19 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
232 PSIG; 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-42 Non-Cycling Refrigerated Air Dryer

QPNC-42 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 42 CFM at 100 PSIG and specifies 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
42 CFM at 100 PSIG; separate metric column 71 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.3 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
232 PSIG; 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-64 Non-Cycling Refrigerated Air Dryer

QPNC-64 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 64 CFM at 100 PSIG and specifies 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
64 CFM at 100 PSIG; separate metric column 109 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.38 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
232 PSIG; 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-83 Non-Cycling Refrigerated Air Dryer

QPNC-83 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 83 CFM at 100 PSIG and specifies 1" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
83 CFM at 100 PSIG; separate metric column 141 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.72 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-106 Non-Cycling Refrigerated Air Dryer

QPNC-106 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 106 CFM at 100 PSIG and specifies 1" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
106 CFM at 100 PSIG; separate metric column 180 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.72 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-127 Non-Cycling Refrigerated Air Dryer

QPNC-127 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 127 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
127 CFM at 100 PSIG; separate metric column 216 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.79 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-144 Non-Cycling Refrigerated Air Dryer

QPNC-144 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 144 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
144 CFM at 100 PSIG; separate metric column 245 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.79 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-184 Non-Cycling Refrigerated Air Dryer

QPNC-184 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 184 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
184 CFM at 100 PSIG; separate metric column 313 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
115/1/60 V / phase / Hz; 0.88 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-229 Non-Cycling Refrigerated Air Dryer

QPNC-229 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 229 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
229 CFM at 100 PSIG; separate metric column 389 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
230/1/60 V / phase / Hz; 1.11 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-271 Non-Cycling Refrigerated Air Dryer

QPNC-271 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 271 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
271 CFM at 100 PSIG; separate metric column 460 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
230/1/60 V / phase / Hz; 1.29 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-297 Non-Cycling Refrigerated Air Dryer

QPNC-297 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 297 CFM at 100 PSIG and specifies 1 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
297 CFM at 100 PSIG; separate metric column 505 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
230/1/60 V / phase / Hz; 2 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 1 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-354 Non-Cycling Refrigerated Air Dryer

QPNC-354 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 354 CFM at 100 PSIG and specifies 2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
354 CFM at 100 PSIG; separate metric column 601 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 2.67 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-424 Non-Cycling Refrigerated Air Dryer

QPNC-424 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 424 CFM at 100 PSIG and specifies 2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
424 CFM at 100 PSIG; separate metric column 720 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 2.67 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-530 Non-Cycling Refrigerated Air Dryer

QPNC-530 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 530 CFM at 100 PSIG and specifies 2 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
530 CFM at 100 PSIG; separate metric column 900 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 2.75 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 2 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-636 Non-Cycling Refrigerated Air Dryer

QPNC-636 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 636 CFM at 100 PSIG and specifies 2 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
636 CFM at 100 PSIG; separate metric column 1081 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 3.8 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 2 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-750 Non-Cycling Refrigerated Air Dryer

QPNC-750 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 750 CFM at 100 PSIG and specifies 3" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
750 CFM at 100 PSIG; separate metric column 1275 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 5.81 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 3" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-1000 Non-Cycling Refrigerated Air Dryer

QPNC-1000 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 1000 CFM at 100 PSIG and specifies 3" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
1000 CFM at 100 PSIG; separate metric column 1700 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 6.03 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 3" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-1250 Non-Cycling Refrigerated Air Dryer

QPNC-1250 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 1250 CFM at 100 PSIG and specifies 3" NPT connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
1250 CFM at 100 PSIG; separate metric column 2125 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 6.75 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 3" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-1600 Non-Cycling Refrigerated Air Dryer

QPNC-1600 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 1600 CFM at 100 PSIG and specifies 4" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
1600 CFM at 100 PSIG; separate metric column 2720 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 7.84 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 4" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-1800 Non-Cycling Refrigerated Air Dryer

QPNC-1800 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 1800 CFM at 100 PSIG and specifies 4" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
1800 CFM at 100 PSIG; separate metric column 3060 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 9.43 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 4" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-2200 Non-Cycling Refrigerated Air Dryer

QPNC-2200 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 2200 CFM at 100 PSIG and specifies 4" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
2200 CFM at 100 PSIG; separate metric column 3740 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 9.5 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 4" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-2500 Non-Cycling Refrigerated Air Dryer

QPNC-2500 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 2500 CFM at 100 PSIG and specifies 6" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
2500 CFM at 100 PSIG; separate metric column 4250 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 9.71 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 6" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-3000 Non-Cycling Refrigerated Air Dryer

QPNC-3000 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 3000 CFM at 100 PSIG and specifies 6" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
3000 CFM at 100 PSIG; separate metric column 5097 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 11.39 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 6" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation
Source reference illustration

Retained source illustration. Series illustration; not an exact model or configuration photograph.

Quincy Compressor

Source-backed reference

Quincy QPNC-3500 Non-Cycling Refrigerated Air Dryer

QPNC-3500 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 3500 CFM at 100 PSIG and specifies 6" Flange connections; duty correction and the exact electrical execution remain part of selection.

Rated flow
3500 CFM at 100 PSIG; separate metric column 5946 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Standard electrics and full-load input
460/3/60 V / phase / Hz; 12.81 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
Maximum pressure and connection
203 PSIG; 6" Flange inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation

Generic area illustration; not an exact model or configuration. Illustrative assortment of compressors, refrigerated and desiccant dryers, filters and pneumatic hose

Generic area illustration; not an exact model or configuration. Illustrative assortment of welding power sources, torches, electrodes, filler wires and cutting consumables

Welding, Cutting & Surface Engineering

Welding, brazing and surface engineering materials and equipment grouped by process: consumables for SMAW, TIG, MIG/MAG, FCAW and SAW; brazing alloys; hardfacing and wear protection; thermal spray and cladding powders; welding equipment; cutting and beveling; surface preparation.

Brands: Wall Colmonoy

Electrical, Cable & Power

Electrical, Cable & Power

Browse supplier product lines and request categories. Each Brand guide helps you describe your requirement for a quotation.

ASH Cable

Power, control and instrumentation cables.

ASH Cable

Power cables

Low-voltage power cable constructions for fixed building and industrial installations. Choose conductor, insulation, armour and installation requirements against the exact cable datasheet.

Request a quote

Control cables

Cable constructions for control wiring in industrial systems. Define circuit duty and construction separately from low-level instrumentation signals.

Request a quote

Instrumentation cables

Cable constructions for measurement and process-instrumentation signals. Match pair or triad arrangement, screening and installation conditions to the signal circuit.

Request a quote
View brand

Lumel

Electrical meters, power analyzers, ammeters, shunts and measurement transducers.

Lumel

Energy meters

Electrical energy metering for installation monitoring. Specify the network, current connection and required reading or communication functions.

Request a quote

Network meters and power analyzers

Meters and analyzers for electrical-network supervision and energy monitoring. Select measurement, recording and interface functions for the installation.

Request a quote

Digital and analogue panel meters

Panel instruments for local electrical and process indication, including ammeter duties where supported by the selected instrument. Match the quantity, input and display to the panel.

Request a quote

Electrical transducers and signal separators

Electrical measurement conversion and signal separation for automation. Match the input quantity and standard output to the receiving system.

Request a quote

Current transformers and shunts

Measurement inputs for electrical current circuits. Keep transformer and passive-shunt selection distinct and match the selected device to its meter or transducer.

Request a quote

Controllers and power regulation

Control functions for power factor, temperature and electrical power regulation. Choose the control task and compatible sensing and output interfaces.

Request a quote

Switching and protection

Published switching, protection and bay-control areas. Define the circuit duty and required control or protection function for technical selection.

Request a quote

Recording, I/O and data logging

Recording and data-interface functions for monitoring systems. Define channels, signals and storage or communication needs before choosing a configuration.

Request a quote

Temperature and radiation measurement

Separate sensing and monitoring areas for temperature and radiation. Select against the measured phenomenon, installation and receiving-system requirements.

Request a quote

Test, calibration and accessories

Portable electrical test instruments, calibrators and instrument accessories. Match the measurement or calibration task and exact host-device compatibility.

Request a quote

Software and automation systems

Software and automation-system areas for instrument configuration and monitoring. Describe the installed devices, required functions and integration environment.

Request a quote

Power supplies and photovoltaic inverters

Published power-supply and photovoltaic-inverter areas. Specify the electrical role and installation conditions; confirm model-specific functions in the relevant documentation.

Request a quote
View brand

Circutor

Electrical metering, power analyzers, ammeters, shunts and electrical transducers.

Circutor

Fixed power analyzers

Fixed electrical-network measurement and power-quality analysis. Define the required measurements and event-recording functions before selecting an analyzer.

Request a quote

Current transformers and shunts

Current measurement inputs for electrical installations. Distinguish AC current transformers, converter-equipped devices and DC shunts for the receiving instrument.

Request a quote

Automation and control

Control-system accessories within the measurement and control area. Match the accessory to its host device and required system function.

Request a quote

Portable power analyzers

Portable electrical-network measurement for surveys and diagnostics. Select the analyzer together with compatible clamps, sensors and connection accessories.

Request a quote

Digital instruments and electrical transducers

Digital electrical indication and measurement-signal conversion. Match the measured input, displayed quantity and output to the installation.

Request a quote

Analogue instruments and ammeters

Analogue panel indication including AC and DC ammeters, voltmeters and related electrical instruments. Define the quantity, scale and input configuration.

Request a quote

Energy metering

Electrical energy metering for partial-consumption monitoring. Define the network, current connection and required readout or communications for the meter.

Request a quote

Protection and control

Electrical protection, relays and related control equipment. Select the protection function and coordination requirements for the specific circuit.

Request a quote

Power factor correction and harmonic filtering

Equipment for reactive-power compensation and harmonic mitigation. Provide measured network conditions and the target function for an engineered selection.

Request a quote

Renewable energies

Published solar-canopy and battery energy-storage system areas. Define the site, energy duty and system interfaces for project-specific review.

Request a quote

Software

Cloud and on-premise software areas for monitoring and management. Define compatible devices, required functions and the deployment environment.

Request a quote

Industrial IoT and automation

Industrial data, edge-control and communication equipment. Match the data sources, I/O and communication paths to the integration task.

Request a quote
View brand
Instrumentation

Instrumentation

Browse supplier product lines and request categories. Each Brand guide helps you describe your requirement for a quotation.

Badger Meter

Flow measurement, water-quality monitoring and control instruments.

Badger Meter

ModMAG electromagnetic flow meters

Electromagnetic flow measurement for conductive liquids in water, wastewater and industrial processes. Match the sensor and converter to the fluid and installation.

Request a quote

E-Series ultrasonic water meters

Ultrasonic metering for utility-water service. Select the service configuration, flow profile and registration or communication requirements for the application.

Request a quote

Hedland variable-area flow meters

Direct-reading variable-area instruments for liquid, gas and hydraulic service. Select the scale and materials for the actual medium and operating conditions.

Request a quote

Industrial oval-gear flow meters

Positive-displacement flow measurement for suitable clean process fluids, including viscous liquids. Confirm fluid compatibility, viscosity and installation before selection.

Request a quote

Research Control Valves

Control valves for small-flow process duties. Provide the fluid, sizing basis and operating conditions so trim, body and actuation can be reviewed.

Request a quote

s::can water-quality monitoring

Online water-quality instruments and platforms for drinking water, wastewater and environmental monitoring. Define the parameters and installation before choosing a sensor system.

Request a quote

ATi water-quality and gas instruments

Water-quality and fixed gas-detection instruments. Select the measured parameter or gas, measurement range, installation and output for the duty.

Request a quote
View brand

Winters Instruments

Pressure gauges, process transmitters, temperature instruments and accessories.

Winters Instruments

Pressure gauges

Local pressure indication for process and general instrument duties. Select the gauge against the medium, operating pressure, materials and installation.

Request a quote

Pressure transmitters and process transducers

Pressure-to-signal instruments for process monitoring and control. These measure process pressure; specify the pressure reference, medium and receiving-system signal.

Request a quote

Pressure switches

Pressure-operated switching for process and equipment control. Define the switching duty, set point and reset behaviour before choosing a configuration.

Request a quote

Diaphragm seals

Process-isolation assemblies for pressure instruments. Match the seal, fill system and instrument to the medium and installation conditions.

Request a quote

Differential pressure instruments

Gauges and transmitters for differential-pressure monitoring. Define both pressure connections and operating conditions, including the required local or transmitted indication.

Request a quote

Commercial temperature and thermometers

Local temperature indication for commercial and industrial applications. Select the sensing arrangement, connection and display for the installation.

Request a quote

RTDs and thermocouples

Temperature sensors and related transmitter equipment. Match the sensing element, assembly and signal interface to the required temperature measurement.

Request a quote

Thermowells

Protective process fittings for temperature instruments. Match the thermowell dimensions, connection and materials to the process and selected sensor.

Request a quote

Humidity and environmental sensors

Building and environmental sensing areas for humidity, air quality and detection duties. Define the measured condition and location for the exact sensor selection.

Request a quote

Valves, manifolds and accessories

Instrument connection, isolation and accessory equipment. Match each component to the pressure instrument, process conditions and required connection arrangement.

Request a quote
View brand
Fire Protection

Fire Protection

Browse supplier product lines and request categories. Each Brand guide helps you describe your requirement for a quotation.

HD Fire Protect

Fire-protection equipment, valves, nozzles and engineered suppression systems.

HD Fire Protect

Sprinklers, alarm valves and accessories

Sprinkler-system components including sprinklers, flexible connections and alarm-valve equipment. Select against the system design and installation requirements.

Request a quote

Deluge valves and pre-action systems

Deluge-valve, skid and pre-action system areas. Define the protected hazard, release method and system interfaces for design review.

Request a quote

Water spray nozzles

Water-spray nozzle equipment for engineered fire-protection arrangements. Match the spray characteristics and installation to the protected equipment.

Request a quote

Monitors and monitor nozzles

Firefighting monitors and compatible monitor nozzles. Define the water or foam duty, operation and installation before selecting the assembly.

Request a quote

Foam equipment and suppression systems

Foam proportioning, discharge, concentrate and mobile-equipment areas. Selection depends on the fire hazard, system design and compatible foam formulation.

Request a quote

System valves and accessories

Valves and accessories for fire-protection piping systems. Match the function, connection and materials to the designed system.

Request a quote

Pressure reducing valves

Pressure-reducing valve equipment for fire-protection systems. Provide inlet, outlet and flow conditions for review against the exact valve documentation.

Request a quote

Handline nozzles

Handline nozzle equipment for firefighting hose applications. Select the nozzle duty and operating requirements for the intended hose arrangement.

Request a quote

Gas suppression systems

Carbon-dioxide and inert-gas suppression system areas. System suitability depends on the protected enclosure, hazard and engineered safety requirements.

Request a quote

Custom engineered systems

Project-engineered skid and suppression assemblies. Define the system scope, operating conditions and interfaces for a coordinated technical proposal.

Request a quote
View brand
IT Products & Solutions

IT Products & Solutions

Infrastructure, cybersecurity, software and managed support. Explore the dedicated Maratej IT website.

Explore Maratej IT

Can't find the item?

Describe the item or send your list and specification, and we will review it against your requirement and reply with a quotation.