QPNC-750 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 750 CFM at 100 PSIG and specifies 3" NPT connections; duty correction and the exact electrical execution remain part of selection.
- Rated flow
- 750 CFM at 100 PSIG; separate metric column 1275 m³/h at 7 BAR
CFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
- Standard electrics and full-load input
- 460/3/60 V / phase / Hz; 5.81 kW
CFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
- Maximum pressure and connection
- 203 PSIG; 3" NPT inlet/outlet
Exact listed execution; connection spelling retained from source.
- Dimensions
- 40 × 44 × 63 in (length × width × height)
Published dimensions; installation/service clearances require confirmation.
- Refrigerant
- R513a
Exact table row; no refrigerant alternatives inferred.
- Correction reference points
- 100 PSIG pressure factor 1.0; 100°F inlet factor 1.0; 100°F ambient factor 1.0; 37–39°F dew-point correction factor 1
Only printed QPNC 750–3000 bands apply; actual site correction is still required.
Requested values remain separate from recorded product specifications.