Explore equipment, consumables and technical specifications for industrial procurement. Select your requirements and request a quotation.

Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
Quincy Compressor
Source-backed reference
QGV-400 is a Quincy variable-speed rotary-screw compressor. Its 400 hp / 315 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
- Published pressure/flow pair
- 2113.0 ACFM with pressure column 100 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Published pressure/flow pair
- 1973.5 ACFM with pressure column 125 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Power
- 400 hp; 315 kWPower columns as printed; motor rating versus total package input is not independently established.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-230 is a Quincy heatless desiccant dryer. The manufacturer lists 230 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 230 CFM at 100 PSIG; purge 41 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 1.5" NPT inlet/outlet; 29 × 38 × 67 in; approximate 750 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-320 is a Quincy heatless desiccant dryer. The manufacturer lists 320 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 320 CFM at 100 PSIG; purge 58 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 1.5" NPT inlet/outlet; 34 × 43 × 68 in; approximate 915 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-390 is a Quincy heatless desiccant dryer. The manufacturer lists 390 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 390 CFM at 100 PSIG; purge 70 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 1.5" NPT inlet/outlet; 34 × 43 × 68 in; approximate 981 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-530 is a Quincy heatless desiccant dryer. The manufacturer lists 530 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 530 CFM at 100 PSIG; purge 95 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 2" NPT inlet/outlet; 38 × 44 × 72 in; approximate 1323 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-635 is a Quincy heatless desiccant dryer. The manufacturer lists 635 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 635 CFM at 100 PSIG; purge 114 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 2" NPT inlet/outlet; 44 × 46 × 73 in; approximate 1433 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-750 is a Quincy heatless desiccant dryer. The manufacturer lists 750 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 750 CFM at 100 PSIG; purge 127 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 80 × 44 × 103 in; approximate 2830 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-900 is a Quincy heatless desiccant dryer. The manufacturer lists 901 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 901 CFM at 100 PSIG; purge 153 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 80 × 43 × 103 in; approximate 3030 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-1100 is a Quincy heatless desiccant dryer. The manufacturer lists 1123 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1123 CFM at 100 PSIG; purge 191 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 80 × 43 × 103 in; approximate 3312 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-1370 is a Quincy heatless desiccant dryer. The manufacturer lists 1377 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1377 CFM at 100 PSIG; purge 234 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 83 × 43 × 96 in; approximate 3778 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-1800 is a Quincy heatless desiccant dryer. The manufacturer lists 1801 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1801 CFM at 100 PSIG; purge 306 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 102 × 49 × 103 in; approximate 5851 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-2300 is a Quincy heatless desiccant dryer. The manufacturer lists 2331 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 2331 CFM at 100 PSIG; purge 396 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 102 × 49 × 125 in; approximate 7048 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-2800 is a Quincy heatless desiccant dryer. The manufacturer lists 2818 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 2818 CFM at 100 PSIG; purge 479 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 116 × 49 × 125 in; approximate 7676 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QHD-3600 is a Quincy heatless desiccant dryer. The manufacturer lists 3602 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 3602 CFM at 100 PSIG; purge 612 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 115/1/60 V / phase / Hz; 0.06 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 6" RF inlet/outlet; 121 × 69 × 132 in; approximate 10702 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-850 is a Quincy heated-purge desiccant dryer. The manufacturer lists 850 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 850 CFM at 100 PSIG; purge 85 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 7.9 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 76 × 47 × 106 in; approximate 2288 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-1050 is a Quincy heated-purge desiccant dryer. The manufacturer lists 1050 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1050 CFM at 100 PSIG; purge 105 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 10.8 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 76 × 47 × 106 in; approximate 2491 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-1220 is a Quincy heated-purge desiccant dryer. The manufacturer lists 1220 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1220 CFM at 100 PSIG; purge 122 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 11.8 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 3" RF inlet/outlet; 82 × 47 × 98 in; approximate 3109 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-1700 is a Quincy heated-purge desiccant dryer. The manufacturer lists 1700 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 1700 CFM at 100 PSIG; purge 170 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 15.8 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 97 × 54 × 106 in; approximate 4643 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-2000 is a Quincy heated-purge desiccant dryer. The manufacturer lists 2000 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 2000 CFM at 100 PSIG; purge 200 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 18 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 97 × 54 × 106 in; approximate 5027 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-2600 is a Quincy heated-purge desiccant dryer. The manufacturer lists 2600 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 2600 CFM at 100 PSIG; purge 260 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 22.3 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 4" RF inlet/outlet; 90 × 67 × 131 in; approximate 6063 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-3000 is a Quincy heated-purge desiccant dryer. The manufacturer lists 3000 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 3000 CFM at 100 PSIG; purge 300 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 26.3 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 6" RF inlet/outlet; 90 × 67 × 131 in; approximate 7469 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Representative image from another reference in this family; not this model. Retained source illustration. Model candidate illustration; exact execution and configuration are not approved.
View the illustrated source reference: Quincy QCMD 4 Compact Heatless Desiccant Air Dryer
Quincy Compressor
Source-backed reference
QHP-3400 is a Quincy heated-purge desiccant dryer. The manufacturer lists 3400 CFM at 100 PSIG, with purge consumption stated separately. Select the drying duty, electrical execution and installation arrangement against the exact model data.
- Rated inlet flow and purge
- 3400 CFM at 100 PSIG; purge 340 CFMPublished inlet-flow and purge columns remain separate; no net-flow subtraction or SCFM equivalence inferred.
- Electrical execution and average input
- 460/3/60 V / phase / Hz; 29 kWExact published execution; other series-level electrical options are not silently combined.
- Connection, dimensions and weight
- 6" RF inlet/outlet; 90 × 67 × 131 in; approximate 7848 lbLength × width × height; dimensions for the basic dryer.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QPNC-13 is a Quincy non-cycling refrigerated dryer for compressed-air moisture control. The specifications describe the single QPNC-13 row, including its electrical execution and connection size; larger QPNC models and high-temperature QRHT dryers remain separate selections.
- Rated flow
- 13 CFM at 100 PSIG; separate printed metric column 22 m³/h at 7 BARPrinted reference-pressure bases retained; no CFM/SCFM/FAD equivalence inferred.
- Electrical execution
- 115 V / 1 phase / 60 Hz; full-load input 0.16 kWkW includes air-cooled fan motors according to the table note.
- Pressure / connections
- Maximum 232 PSIG; inlet/outlet 1/2-in NPTExact QPNC-13 row; inlet/ambient correction factors still govern sizing.
Request a quotation →

Retained source illustration. Series illustration; not an exact model or configuration photograph.
Quincy Compressor
Source-backed reference
QPNC-21 is a Quincy non-cycling refrigerated compressed-air dryer. Its published row rates 21 CFM at 100 PSIG and specifies 1/2" NPT connections; duty correction and the exact electrical execution remain part of selection.
- Rated flow
- 21 CFM at 100 PSIG; separate metric column 36 m³/h at 7 BARCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
- Standard electrics and full-load input
- 115/1/60 V / phase / Hz; 0.16 kWCFM column at 100 PSIG; separate m3/hr column at 7 BAR. These labels are retained; no SCFM/FAD equivalence inferred. kW includes air-cooled fan motors.
- Maximum pressure and connection
- 232 PSIG; 1/2" NPT inlet/outletExact listed execution; connection spelling retained from source.
Request a quotation →