Coiled Tubing Connectors

Roll-on and slip-connector configurations with associated crimping-tool requirements.

Configure your requirements
Double Roll-On Connector, 1-1/4 in Tubing
Technical illustration: Double Roll-On Connector, 1-1/4 in Tubing. Diagram not to scale; final configuration must be confirmed.

Sizes & capacities

Manufacturer reference configurations

Compare published specifications for each configuration, then select a reference or enter your own requirements. Supply and the final configuration are confirmed in the quotation.

Double Roll-On Connector, 1-1/4 in Tubing / وصلة مزدوجة بالكبس للأنابيب بمقاس 1-1/4 بوصة

Documented example execution; listed values apply only to this example. / مثال تنفيذ موثق؛ تنطبق القيم المدرجة على هذا المثال فقط.

Coiled tubing diameter / قطر الأنبوب الملفوف
1-1/4 in
Make-up length / طول التركيب
8.00 in
Attachment method / طريقة التثبيت
Crimping the tubing outside diameter / كبس القطر الخارجي للأنبوب
Body construction / تصميم الجسم
One piece / قطعة واحدة
Sealing / الإحكام
O-ring seals / حلقات إحكام دائرية

Your specification

Configure your product requirement

Enter the capacity and site requirements you need. Your selections carry into the RFQ and remain editable before submission.

Essential operating requirements

Optional example only. Its values apply only to the stated execution; confirm the final configuration in your quotation.

Describe the operating task and installation context.

Include size, length, connection type and drawings where applicable; state units.

State working pressure, temperature and units. Distinguish working and test pressure.

Describe the fluid, well conditions and any corrosive or sour-service requirements.

For matching equipment, provide its maker, model, serial number, interface or drawing. Compatibility must be confirmed.

Specify required drawings, material records, test reports, standards and inspection scope. No certification is presumed.

State whether a complete item, assembly, accessory or spare part is needed, with part references if available.

Next: contact details, quantity and delivery. Leave unknown requirements blank and request help in the RFQ.

Selection guidance

Specify the application, size, connection, operating pressure and temperature, fluid or service conditions, quantity and required documentation. Confirm the exact configuration before ordering.

Technical notes

The specification tables below describe documented example configurations only. Values are not interchangeable between executions; final dimensions, interfaces, materials and service requirements must be confirmed. Configuration enquiry only. Ratings, materials, connections and standards are specific to the selected execution and must be confirmed. No cross-model interchangeability or site approval is implied.