Directional Control Valves

Select a valve by its circuit function and return behaviour before checking port size, flow and supply. Compare 3/2, 5/2 and 5/3 body references with their own minimum operating pressure.

Configure your requirementsRequest spare parts →
Representative illustration of the product type; dimensions and supplied accessories are defined separately.
Representative illustration of the product type; dimensions and supplied accessories are defined separately.

Sizes & capacities

Manufacturer reference configurations

Compare published specifications for each configuration, then select a reference or enter your own requirements. Supply and the final configuration are confirmed in the quotation.

14 documented configurations. Review one specification at a time; your custom requirements are retained.

5/2 monostable · G1/8

The port size, function, nominal flow and minimum pressure belong to this valve body execution. Coil supply, connector, pilot arrangement and manifold compatibility require separate selection.

Function
5/2 monostable
Port thread
G1/8
Nominal flow
700 Nl/min
Flow basis
Source nominal flow; confirm pressure-drop basis for sizing
Operating pressure
2.5–10 bar
Temperature
0–60°C; dry air required below 0°C, minimum −20°C
Valve body
Aluminium
Spool / seals
Stainless steel / NBR
Actuation
Single solenoid + mechanical spring
Coil / connector
Specify separately; no coil voltage is implied by the body reference
Datasheet revision
2026/04

Your specification

Configure your product requirement

Enter the capacity and site requirements you need. Your selections carry into the RFQ and remain editable before submission.

Essential operating requirements

Select a documented reference, or leave blank and describe an unlisted requirement. Reference ratings remain separate from your requested specification.

Additional dimensions and application details
Equipment identification & spare parts

Identify the installed equipment and the part you need. Add nameplate photos, drawings or a parts-list extract in the RFQ attachments step.

Next: contact details, quantity and delivery. Leave unknown requirements blank and request help in the RFQ.

Applications

Control of single- and double-acting actuators, machine sequences and air circuits.

Selection guidance

Choose normally open or normally closed, monostable or bistable, and the required 5/3 centre condition. Specify G or NPT thread, required flow and pressure drop, coil voltage, AC/DC, frequency, connector and manual override.

Technical notes

The G1/8 and G1/4 examples are separate source rows. Nominal flow is not a guaranteed installed flow. Coil, connector and any safety function are not inferred from a basic directional-valve reference.