Explore equipment, consumables and technical specifications for industrial procurement. Select your requirements and request a quotation.
Wire Feeder Controls & Drive Gears
Reference configuration — confirm the required execution when enquiring.
Source-specific replacement-part execution. Catalogue identifiers are not maker models or universal fit claims.
- Component type
- Remote control
- Source execution detail
- Up/Down
- Execution scope
- Source-specific feeder spare; actual installed model, version, article and interface require verification.
Request a quotation →
Wire Feeder Controls & Drive Gears
Reference configuration — confirm the required execution when enquiring.
Source-specific replacement-part execution. Catalogue identifiers are not maker models or universal fit claims.
- Component type
- Remote control
- Source execution detail
- Potentiometer
- Execution scope
- Source-specific feeder spare; actual installed model, version, article and interface require verification.
Request a quotation →
Wire Feeder Controls & Drive Gears
Reference configuration — confirm the required execution when enquiring.
Source-specific replacement-part execution. Catalogue identifiers are not maker models or universal fit claims.
- Component type
- Drive gear
- Source execution detail
- Plastics
- Execution scope
- Source-specific feeder spare; actual installed model, version, article and interface require verification.
Request a quotation →
Coiled Tubing Downhole Tools
Reference configuration — confirm the required execution when enquiring.
Documented example execution; listed values apply only to this example. / مثال تنفيذ موثق؛ تنطبق القيم المدرجة على هذا المثال فقط.
- Outside diameter / القطر الخارجي
- 1.500 in
- Inside diameter / القطر الداخلي
- 0.688 in
- Length option / خيار الطول
- 2 ft
Request a quotation →
Submerged Arc Welding Fluxes
Reference configuration — confirm the required execution when enquiring.
This grain-size and packaging execution is listed in the identified source sheet. It is not a claim of current stock or a wire/flux procedure qualification. Confirm the nominated wire grade, WPS, supply packaging and latest handling instructions before quotation.
- Process
- SAW
- Flux type
- Agglomerated fluoride-basic
- Flux classification
- EN ISO 14174: S A FB 1 55 AC H5
Request a quotation →
Submerged Arc Welding Fluxes
Reference configuration — confirm the required execution when enquiring.
This grain-size and packaging execution is listed in the identified source sheet. It is not a claim of current stock or a wire/flux procedure qualification. Confirm the nominated wire grade, WPS, supply packaging and latest handling instructions before quotation.
- Process
- SAW
- Flux type
- Agglomerated fluoride-basic
- Flux classification
- EN ISO 14174: S A FB 1 55 AC H5
Request a quotation →
Submerged Arc Welding Fluxes
Reference configuration — confirm the required execution when enquiring.
This grain-size and packaging execution is listed in the identified source sheet. It is not a claim of current stock or a wire/flux procedure qualification. Confirm the nominated wire grade, WPS, supply packaging and latest handling instructions before quotation.
- Process
- SAW
- Flux type
- Agglomerated fluoride-basic
- Flux classification
- EN ISO 14174: S A FB 1 55 AC H5
Request a quotation →
Submerged Arc Welding Fluxes
Reference configuration — confirm the required execution when enquiring.
This grain-size and packaging execution is listed in the identified source sheet. It is not a claim of current stock or a wire/flux procedure qualification. Confirm the nominated wire grade, WPS, supply packaging and latest handling instructions before quotation.
- Process
- SAW
- Flux type
- Agglomerated fluoride-basic
- Flux classification
- EN ISO 14174: S A FB 1 55 AC H5
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G1
- Outlet setting range
- 0.5–4 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G1
- Outlet setting range
- 0.5–10 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Modular Pneumatic Air Filters
Reference configuration — confirm the required execution when enquiring.
Particle filter execution. The drain pressure range is part of the configuration. This filter alone does not specify dryer dew point, oil-vapour removal or the air-quality class of an entire system.
- Port thread
- G1
- Filtration
- 5 µm
- Drain
- Automatic
Request a quotation →
Modular Pneumatic Air Filters
Reference configuration — confirm the required execution when enquiring.
Particle filter execution. The drain pressure range is part of the configuration. This filter alone does not specify dryer dew point, oil-vapour removal or the air-quality class of an entire system.
- Port thread
- G1
- Filtration
- 25 µm
- Drain
- Manual / semi-automatic
Request a quotation →
Air-Line Lubricators
Reference configuration — confirm the required execution when enquiring.
Oil-mist lubrication reference. Minimum activation flow is not maximum delivery flow. Use only when the downstream equipment requires lubrication; once lubrication is adopted it must be maintained.
- Port thread
- G1
- Oil capacity
- 230 cm³
- Minimum flow at 1 bar
- 50 l/min
Request a quotation →
Filter, Regulator & Lubricator Assemblies
Reference configuration — confirm the required execution when enquiring.
Matched three-module assembly with separate filter, regulator and lubricator. It is not a universal mix-and-match kit. Lockable isolation, soft start, coalescing filtration and other combinations require their own selection.
- Port thread
- G1
- Modules
- 5 µm filter + relieving regulator + lubricator
- Filter / oil capacity
- 85 / 230 cm³
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G1/2
- Outlet setting range
- 0.5–4 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G1/2
- Outlet setting range
- 0.5–10 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Modular Pneumatic Air Filters
Reference configuration — confirm the required execution when enquiring.
Particle filter execution. The drain pressure range is part of the configuration. This filter alone does not specify dryer dew point, oil-vapour removal or the air-quality class of an entire system.
- Port thread
- G1/2
- Filtration
- 5 µm
- Drain
- Automatic
Request a quotation →
Modular Pneumatic Air Filters
Reference configuration — confirm the required execution when enquiring.
Particle filter execution. The drain pressure range is part of the configuration. This filter alone does not specify dryer dew point, oil-vapour removal or the air-quality class of an entire system.
- Port thread
- G1/2
- Filtration
- 25 µm
- Drain
- Manual / semi-automatic
Request a quotation →
Air-Line Lubricators
Reference configuration — confirm the required execution when enquiring.
Oil-mist lubrication reference. Minimum activation flow is not maximum delivery flow. Use only when the downstream equipment requires lubrication; once lubrication is adopted it must be maintained.
- Port thread
- G1/2
- Oil capacity
- 170 cm³
- Minimum flow at 1 bar
- 17 l/min
Request a quotation →
Filter, Regulator & Lubricator Assemblies
Reference configuration — confirm the required execution when enquiring.
Matched three-module assembly with separate filter, regulator and lubricator. It is not a universal mix-and-match kit. Lockable isolation, soft start, coalescing filtration and other combinations require their own selection.
- Port thread
- G1/2
- Modules
- 5 µm filter + relieving regulator + lubricator
- Filter / oil capacity
- 55 / 170 cm³
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G3/4
- Outlet setting range
- 0.5–4 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G3/4
- Outlet setting range
- 0.5–4 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G3/4
- Outlet setting range
- 0.5–10 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →
Pneumatic Pressure Regulators
Reference configuration — confirm the required execution when enquiring.
Pressure regulator execution with a defined adjustment range. Inlet pressure, regulated pressure, flow and droop are different requirements. Flow is selected against the applicable characteristic curve.
- Port thread
- G3/4
- Outlet setting range
- 0.5–10 bar
- Maximum inlet pressure
- 16 bar
Request a quotation →