Quincy QGDV-20 Variable Speed Rotary Screw Air Compressor
Reference information only. Confirm the actual equipment, configuration and supplied contents in the quotation. This reference does not confirm stock, installed compatibility or a certified supplied item.
Enquire about this referenceView the illustrated source reference: Quincy QGSV-5 Variable Speed Rotary Screw Air Compressor 5 HP
Reference overview
QGDV-20 is a Quincy variable-speed rotary-screw compressor. Its 20 hp / 15 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
Recorded reference facts
- Published pressure/flow pair
- 102.6 ACFM with pressure column 100 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Published pressure/flow pair
- 96.2 ACFM with pressure column 125 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Published pressure/flow pair
- 87.1 ACFM with pressure column 150 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Power
- 20 hp; 15 kWPower columns as printed; motor rating versus total package input is not independently established.
- Weight
- 1069 lbPublished package row; final execution and transport requirements need confirmation.
- Sound level
- 67 dBAPrinted dBA row; measurement distance/load basis not fully specified here. No site noise guarantee.
Applications
- Industrial compressed-air generation at the selected pressure and flow.
- Variable-load air systems.
Configurations
- QGDV-20 · Pressure as printed psi: 100 · Flow acfm: 102.6 · Scope: Exact published duty row; no interpolation
- QGDV-20 · Pressure as printed psi: 125 · Flow acfm: 96.2 · Scope: Exact published duty row; no interpolation
- QGDV-20 · Pressure as printed psi: 150 · Flow acfm: 87.1 · Scope: Exact published duty row; no interpolation
Operating conditions and scope
- The length, width and height columns do not state units. Do not assume the dimensions are in inches.
- Electrical voltage/phase/frequency and exact installed configuration require manufacturer confirmation.
- Confirm the applicable ISO 1217 test basis with the manufacturer.