مرجع موثق من المصدر
Quincy QGDV-30 Variable Speed Rotary Screw Air Compressor
معلومات مرجعية فقط. يجب تأكيد المعدات الفعلية والتكوين ومحتويات التوريد في عرض السعر. لا يثبت هذا المرجع المخزون أو التوافق مع المعدات المركبة أو اعتماد القطعة الموردة.
استفسر عن هذا المرجعنبذة عن المرجع
QGDV-30 is a Quincy variable-speed rotary-screw compressor. Its 30 hp / 22 kW source entry has separate pressure/flow rows below; these are individual published duties rather than a continuous operating envelope.
البيانات المرجعية المسجلة
- Published pressure/flow pair
- 154.5 ACFM with pressure column 100 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Published pressure/flow pair
- 141.3 ACFM with pressure column 125 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Published pressure/flow pair
- 124.8 ACFM with pressure column 150 PSIACFM and PSI retained exactly as printed; no SCFM conversion, intermediate duty or cross-row combination inferred.
- Power
- 30 hp; 22 kWPower columns as printed; motor rating versus total package input is not independently established.
- Weight
- 1171 lbPublished package row; final execution and transport requirements need confirmation.
- Sound level
- 69 dBAPrinted dBA row; measurement distance/load basis not fully specified here. No site noise guarantee.
التطبيقات
- Industrial compressed-air generation at the selected pressure and flow.
- Variable-load air systems.
التكوينات
- QGDV-30 · Pressure as printed psi: 100 · Flow acfm: 154.5 · Scope: Exact published duty row; no interpolation
- QGDV-30 · Pressure as printed psi: 125 · Flow acfm: 141.3 · Scope: Exact published duty row; no interpolation
- QGDV-30 · Pressure as printed psi: 150 · Flow acfm: 124.8 · Scope: Exact published duty row; no interpolation
ظروف الاستخدام ونطاق التطبيق
- The length, width and height columns do not state units. Do not assume the dimensions are in inches.
- Electrical voltage/phase/frequency and exact installed configuration require manufacturer confirmation.
- Confirm the applicable ISO 1217 test basis with the manufacturer.